Seller
+380
Display phones
13
13 years on Allbiz
Technical characteristics
- BrandОмега
- Country of manufactureUkraine
- ColorGrey
Description
Signaling limiting resistances CDF - 01 AU (hereinafter - signaling) are designed to provide information on the output resistance value of the resistive sensor installed guaranteed range (band).
Signaling devices are 3NK safety class according to NP 306.2.141.
The degree of protection IP 30 signaling in accordance with GOST 14254.
Working conditions for the application signaling:
- Ambient temperature 1 to 50 ° C;
- relative humidity 80% at 35 ° C;
- Atmospheric pressure from 84 to 106.7 kPa.
Warning has the following characteristic impedance conversion resistive sensor:
- Zone I: d 0 ≤ R ≤ R1max;
- intermediate zone: R1max ≤ R e ≤ RIImin;
- Zone II: RIImin ≤ R e ≤ ∞,
wherein R d - the resistance value of the resistive sensor;
R1max, RIImin - maximum and minimum values of the resistance zones guaranteed signaling according to Table
SPECIFICATIONS |
||
---|---|---|
option guaranteed area alarm |
resistance zone guaranteed alarm zones kohm | |
Zone I (activation) 0 ≤ Rd ≤ R1max |
Zone II (released) RIImin ≤ Rd ≤ ∞ (100000); |
|
CDF - 01 AC - E | from 0 to 2.0 | from 10.0 to 100,000 |
CDF - 01 AS - M | from 0 to 10.0 | from 50.0 to 100,000 |
CDF - 01 - P AS | from 0 to 50.0 | from 220.0 to 100,000 |
CDF - 01 - AC | from 0 to 200.0 | from 1000.0 to 100000 |
Signaling provide alarm when the resistance values of resistive sensors in zones guaranteed signaling light as alarms (zone I), releasing (zone II) and the intermediate Zoni. Warning for malfunctions outputs additional output signal and warning lights "Alarm".
Switching elements commute signaling DC voltage of 220 V at a current of 1 A; AC voltage of 220 V at a current of 1 A.
Warning has intrinsically safe input.
Line length signaling connection with the resistive sensor is not more than 200 m with an inductance of 0.2 mH; 0.02 microfarad capacitance for variants E, M, P and 0.01 microfarads for variant B.
Power signaling from an AC voltage of 220 V (deviation from + 22 to - 33 V) 50 ± 1 Hz frequency.
Power consumption - no more than H B * A.
Dimensions signaling no more than 70x80x210 mm.
Signaling Weight not more than 1.0 kg.
MTBF of not less than 120,000 hours.
Similar company products
Contact the seller
Warning limiting resistances CDF-01 AU