Touch screen semi -automatic Biochemistry Analyzer with 1 year warranty
- Customer pickup,
- Courier
- In detail
Description
Semi automatic biocmheistry Analyser (with congulation)
Technical Specifiction
Test Method
End Point with Standard/Factor
Two point knietics(Fixed time)
Multi Point Knietics
Multi standard upto 8 standards
Biochromatic,Dual wavelength
Absorbance
Coagulation
Optical System
Principal:Photomatric Analysis with Interference Filter
Absorbance Range: 0.0000-3.0000
(Linearity: ±%,Repeatability: 0.001,Resolution: 0.0001)
Spectral Range Selection:Automatic via Filter Wheel
Wavelenghts: 340,405,450,505,546,578,630 nm
+2 Free Positions, ±2 CML Precision
Light Source : 6V 10 W Long Life Tungsten Halogen Lamp
Detector :Photodiode
Thermal System
Peltier Regulated 25°C, 30°C, 37°C & Room Temperature
Accuracy : ± 0.3°C
Cuvettes
Flow Cell : Quartz 32 ul
Path Length : 10mm
Removable Cuvette (Square $ Round)
Printer
Inbuilt Thermal Printer (57mm)
Optional External Printer
Display And Input System
7.0 Inch color touch screen
External Keyboard $ Mouse facility
Suction System
Pressure Auto releasing Peristalic Pump
Suction Volume : 300 ul to 3.0 ml
Air Column facility after each sample to avoid carry over
Test Parameter, Storage & CPU
Test Parameters: Up to 300
2,00,000 test results with editable patient information
Storage of Quality Control And standard results
DDR2 SDRAM : 1 G bit
Flash: 256 MB
ARM Cortex A8,720 MHz
Quality Control
Lew- Jennings Chart Using Westgard's Rule
Auto Drawing of QC figures
Operating Conditions
Temperature: 10°C-37°C
Relative Humidity: <85%
Power Requirement/ Dimensions
Voltage: 100-240 V AC (AutoAdaption)
Frequency: 50/60 HZ
Extenal Power Adaptor : 19 V 4.7 Amp
Dimensions: 400X300X160 (L*W*H)
Weight: 6 Kg
Description
Semi automatic biocmheistry Analyser (with congulation)
Technical Specifiction
Test Method
End Point with Standard/Factor
Two point knietics(Fixed time)
Multi Point Knietics
Multi standard upto 8 standards
Biochromatic,Dual wavelength
Absorbance
Coagulation
Optical System
Principal:Photomatric Analysis with Interference Filter
Absorbance Range: 0.0000-3.0000
(Linearity: ±%,Repeatability: 0.001,Resolution: 0.0001)
Spectral Range Selection:Automatic via Filter Wheel
Wavelenghts: 340,405,450,505,546,578,630 nm
+2 Free Positions, ±2 CML Precision
Light Source : 6V 10 W Long Life Tungsten Halogen Lamp
Detector :Photodiode
Thermal System
Peltier Regulated 25°C, 30°C, 37°C & Room Temperature
Accuracy : ± 0.3°C
Cuvettes
Flow Cell : Quartz 32 ul
Path Length : 10mm
Removable Cuvette (Square $ Round)
Printer
Inbuilt Thermal Printer (57mm)
Optional External Printer
Display And Input System
7.0 Inch color touch screen
External Keyboard $ Mouse facility
Suction System
Pressure Auto releasing Peristalic Pump
Suction Volume : 300 ul to 3.0 ml
Air Column facility after each sample to avoid carry over
Test Parameter, Storage & CPU
Test Parameters: Up to 300
2,00,000 test results with editable patient information
Storage of Quality Control And standard results
DDR2 SDRAM : 1 G bit
Flash: 256 MB
ARM Cortex A8,720 MHz
Quality Control
Lew- Jennings Chart Using Westgard's Rule
Auto Drawing of QC figures
Operating Conditions
Temperature: 10°C-37°C
Relative Humidity: <85%
Power Requirement/ Dimensions
Voltage: 100-240 V AC (AutoAdaption)
Frequency: 50/60 HZ
Extenal Power Adaptor : 19 V 4.7 Amp
Dimensions: 400X300X160 (L*W*H)
Weight: 6 Kg