Currency GBP
Industrial steam TITAN-150 – OOO ROSTZIP | all.biz
Buy Industrial steam TITAN-150
Industrial steam TITAN-150
promyshlennyj_parogenerator_titan_150
promyshlennyj_parogenerator_titan_150

Industrial steam TITAN-150

Products from producer
In stock
Reconfirm the price with seller
For example: +44(50)123-45-67
Shipping:
Russia, Rostov-na-donu
(View map)
+7(9 
Display phones
Less than 1 year old on Allbiz
Quickly responds
Technical characteristics
  • BrandРОСТЗИП
  • Country of manufactureRussia
Description
  1. TITAN - 150
  2. Adjustable saturated temperature: 105 - 165 ° C
  3. One induction unit is installed, steam capacity: 150 kg / steam / hour
  4. Installed power consumption:  53 kW
  5. Adjustable operating pressure steam, 0 - 100% : 7 bar
  6. Supply Voltage: 380V
  7. Current type: AC three - phase
  8. Current frequency: 50 Hz
  9. Three - phase switch: Contactless
  10. It does not require the approval of the supervisory authorities.
  11. To operate the steam generator water treatment required.
  12. Dimensions VhDhSh: 1000h950h600 mm
  13. Mass: 195 kg

The principle of operation of the steam generator:

Feed water which has passed water treatment of the filler (condensate) of the tank is forced to the secondary winding of the inductor and rotary high pressure pump where it proceeds almost instantaneously in steam state. The greater number of inducers, the higher the performance of the steam generator, the steam consumption is directly proportional to productivity. steam generator control of all workflows and Protection, made a programmable relay with the PR - 200 display "ARIES".

The steam generator has nine degrees of protection:

  • vapor pressure, exceeds the limit
  • by the absence of the feedwater in the steam generator system
  • by feedwater temperature, if the temperature has exceeded the allowable limit
  • the temperature of the primary winding of the transformer if the temperature exceeds the allowable limit
  • superheat secondary inductor winding, when the temperature has exceeded the allowable limit 
  • at occurrence of scum in the secondary winding of the inductor
  • temperature of the power unit when the temperature has exceeded the allowable limit
  • the level of humidity inside the steam generator, if the humidity exceeds the allowable limit (for models in which the sensor is installed)
  • to disrupt communication between PR - 200 and its module

Upon request, the steam generator have the capability of manufacturing special design, with the possibility of controlled operating pressure to 10 bar and steam temperature to 180 ° C.

Shipping method
Contact the seller
Industrial steam TITAN-150
Industrial steam TITAN-150
for
by the goods
Your message must contain at least 20 symbols. The message must not be more than 2000 symbols.
Obligatory field is not filled
The field is wrongly filled
The field is wrongly filled
Compare0
ClearSelected items: 0